ATEX Fuel Pumps & Diesel Transfer Pumps
Explosion Proof Fuel Pump Solutions for Industrial Applications
Neftgen supplies industrial ATEX fuel pumps and diesel transfer pumps of European origin, engineered for safe and efficient transfer of diesel, gasoline, kerosene and industrial fuels. These pump systems are widely deployed in fuel stations, tank farms, mobile fuel stations, generator fuel systems, mining sites and industrial fuel transfer operations.
Our primary focus is ATEX certified fuel pumps and diesel transfer systems. Upon request, Neftgen can also supply a wide pump portfolio including gear pumps, self-priming pumps, industrial liquid pumps and high-performance transfer pumps for specialized engineering projects.
ATEX self-priming pumps are specifically designed for hazardous and potentially explosive environments where operational safety, regulatory compliance and long-term reliability are critical.
Key Features
- ATEX certified for hazardous zones
- Explosion-proof motor configurations
- Diesel, gasoline & industrial fuel compatibility
- Self-priming and gear pump options
- Heavy-duty industrial construction
- Corrosion resistant materials
- Long operational lifespan
Applications
- Fuel stations and dispensing systems
- Tank farms and bulk storage facilities
- Mobile containerized fuel stations
- Generator fuel supply systems
- Mining and heavy industry sites
- ATEX classified industrial zones
Neftgen ATEX Pump Projects




From the field: ATEX fuel pumps installed in Neftgen mobile container fuel stations and fuel receiving units.
ATEX Self Priming Fuel Pumps (Diesel, Gasoline & Kerosene)
ATEX self-priming fuel pumps are engineered for explosion-risk environments where safe and reliable fuel transfer is critical. These pumps are ideal for diesel and gasoline transfer in hazardous areas such as fuel depots, tank systems and industrial fuel installations.
General Technical Range
Engineering & Compliance
- Manufactured according to ATEX Directive (II 2G Ex IIB T4)
- Continuous duty operation capability
- Industrial heavy-duty construction
- Explosion-proof motor configurations
- Integrated into Neftgen mobile fuel stations and tank systems
These pumps are widely integrated into Neftgen mobile fuel stations, diesel storage tank systems and engineered fuel transfer skids.
Explosion-Proof Fuel Transfer Engineered for Maximum Safety
Contact Neftgen Engineering for pump selection, system integration and ATEX compliance support.
Request Technical SupportFeatured ATEX Fuel Pump Models
Reliable compact ATEX self-priming pump designed for safe diesel transfer and fuel circulation in hazardous environments.
Flow rate: up to 450 l/min (27 m³/h)
Head: up to 19 m
Power: 1.5 kW | Connections: 2" suction / 2" discharge
Application: Diesel transfer, fuel circulation, mobile fuel stations, small-medium tank systems
Request Datasheet
Heavy-duty ATEX self-priming pump suitable for continuous fuel transfer and industrial fuel handling applications.
Flow rate: up to 900 l/min (54 m³/h)
Head: up to 16 m
Power: 2.2 kW | Connections: 3" suction / 3" discharge
Application: Diesel & gasoline transfer, fuel transfer skids, tank farms, industrial fuel systems
Request Datasheet
High-capacity explosion-proof self-priming pump designed for demanding industrial fuel transfer and continuous duty operation.
Flow rate: up to 2,200 l/min (132 m³/h)
Head: up to 32.5 m
Power: 11 kW | Connections: 4" suction / 4" discharge
Application: Industrial fuel transfer, large tank systems, fuel depots, continuous fuel circulation
Request Datasheet
ATEX Pump Selection Chart — Model by Flow Rate and Head
An explosion-proof diesel pump is selected by flow rate (l/min) and head (m). The chart below lists the catalogue end-of-curve figures for the ATEX certified self-priming pump series, at 50 Hz, 2900 rpm, on water.
| Model | Power (kW) | Connections | Max. flow | Max. head |
|---|---|---|---|---|
| DOMUS | 0.25 | 1" | 35 l/min (2.1 m³/h) | 15 m |
| B1½KQ-A | 0.75 | 1½" | 285 l/min (17 m³/h) | 16 m |
| B2KQ-A | 1.5 | 2" | 450 l/min (27 m³/h) | 19 m |
| B3KQ-A | 2.2 | 3" | 900 l/min (54 m³/h) | 16 m |
| B4KQ-A | 4 | 4" | 1,650 l/min (99 m³/h) | 15.6 m |
| B3XR-A | 4 | 3" | 1,250 l/min (75 m³/h) | 28.5 m |
| B3XR-A | 5.5 | 3" | 1,420 l/min (85 m³/h) | 28.5 m |
| B3XR-A | 7.5 | 3" | 1,460 l/min (88 m³/h) | 34 m |
| B4XR-A | 11 | 4" | 2,200 l/min (132 m³/h) | 32.5 m |
| B4XR-A | 15 | 4" | 2,300 l/min (138 m³/h) | 34 m |
| G2TMK-A | 2.2 | 2" | 400 l/min (24 m³/h) | 33.5 m |
| G2TMK-A | 3 | 2" | 420 l/min (25 m³/h) | 34 m |
| G3TMK-A | 4 | 3" | 900 l/min (54 m³/h) | 35 m |
| G3TMK-A | 5.5 | 3" | 900 l/min (54 m³/h) | 40 m |
| G3TMK-A | 7.5 | 3" | 900 l/min (54 m³/h) | 47 m |
| G3TMK-A | 11 | 3" | 1,150 l/min (69 m³/h) | 55 m |
| B3ZPM-A | 15 | 3" | 1,250 l/min (75 m³/h) | 64 m |
| B3ZPM-A | 18.5 | 3" | 1,250 l/min (75 m³/h) | 71 m |
| B3ZPM-A | 22 | 3" | 1,250 l/min (75 m³/h) | 76 m |
| B4ZPM-A | 22 | 4" | 1,700 l/min (102 m³/h) | 62 m |
| B4ZPM-A | 30 | 4" | 1,750 l/min (105 m³/h) | 65 m |
Important: maximum flow and maximum head are the two ends of the pump curve and are not achieved at the same time — at 2,300 l/min the head is close to zero. For a correct selection, send your duty point (flow + head + fluid + suction lift) and we will select from the pump curve.
Bronze or AISI 316 casing and impeller with SiC seal faces are available for gasoline, jet fuel and corrosive or erosive service. A non-ATEX gear pump range (70–630 l/min, heads to 100 m) is also supplied for diesel, fuel oil and lubricating oils.
Pump Selection & Quotation Form
We only need the data below to size the right ATEX pump. Give us the flow rate and the head — we work out the model and the price.
Bronze or AISI 316 impellers are supplied on request for gasoline and jet fuel service. Selection is settled in one pass when flow and head are given together; a pump chosen on maximum flow alone falls short in the field.
ATEX Self-Priming Pump Range — Operating Envelope
Catalogue end-of-curve figures, 50 Hz. Sorted by flow rate.
How to read this: The two columns are opposite ends of the same curve. Maximum flow and maximum head are never delivered at the same operating point — a pump gives low head at high flow and low flow at high head. Sorting by flow makes this visible: the highest-flow model (B4XR-A) is not the highest-head model; a duty needing 76 m calls for the B3ZPM-A. The real operating point is calculated from fluid type, temperature, viscosity, suction lift and pipe losses. We do the selection — send us your duty point.
Material Selection: Cast Iron, Bronze and AISI 316
What decides a pump's service life is usually not motor power but the material in contact with the fluid. Cast iron is sufficient for standard diesel and gasoline transfer; when the fluid changes, the impeller and casing material must change with it.
| Material | Where it is used | Why |
|---|---|---|
| Cast iron casing + cast iron impeller | Diesel, gasoline, kerosene, fuel oil | Standard execution. Long service life in clean hydrocarbons and the most economical option. |
| Bronze impeller | Ports, marine duty, sites where seawater ingress is possible | Markedly more corrosion-resistant than cast iron in chloride-bearing environments. Also chosen where a non-sparking material is specified. |
| AISI 316 stainless steel | Biodiesel, chemicals, corrosive fluids, non-food process liquids | Biodiesel is hygroscopic — it holds water and turns acidic, accelerating corrosion and impeller wear in cast iron. AISI 316 removes that risk. |
Seal and gasket material is Viton (FKM) in all three executions, resistant to fuels and solvents. If your fluid is not listed, send us the safety data sheet (SDS) — we will check material compatibility and confirm it in writing.
By-pass and Closed-Discharge Operation — Safety Note
A self-priming centrifugal pump does not stop when the discharge line is closed; it keeps turning. The motor power then goes into the liquid as heat and the fluid inside the casing heats up. Because flow is zero, there is nothing carrying that heat away.
This is the point that matters for ATEX. The T4 temperature class on the certificate is a commitment that surface temperature will not exceed 135 °C. Continuous closed-discharge operation can invalidate that commitment — the issue is not that the equipment is damaged, but that the assumption the explosion protection rests on no longer holds.
Motor thermal protection does not solve this. A thermal relay protects the motor winding against overcurrent; it does nothing about the fluid heating inside the casing. The casing keeps heating even while the pump draws less than rated current, and the relay never trips.
For that reason every installation with a shut-off valve on the discharge should include a by-pass line or minimum-flow line: part of the flow returns to suction or to the tank, the liquid in the casing is renewed and temperature stays under control. Gear (positive-displacement) pumps come with an integral by-pass valve; on centrifugal pumps it is solved in the pipework. Send us your P&ID and we will size the line with you.
Full Pump Range Available
In addition to ATEX fuel pumps, Neftgen supplies a wide pump portfolio covering a wide range of industrial fluid transfer applications.
Main Pump Product Lines
- Self-priming fuel and transfer pumps
- Gear pumps for diesel, fuel oil and lubricants
- Centrifugal and liquid transfer pumps
- Oil and lubricant pumps
- Chemical and industrial liquid pumps
- ATEX and non-ATEX industrial pumps
- Engine-driven and electric motor pump units
- Custom pump configurations for fuel systems
Applications
ATEX fuel pumps are engineered for reliable fuel transfer across demanding industrial and infrastructure environments.
Fuel Stations & Tank Farms
Mobile Fuel Stations
Diesel Storage Systems
Generator Fuel Supply
Fuel Transfer Skids
Mining & Construction Systems
Industrial Fuel Circulation
Why Choose Neftgen Fuel Pump Solutions
- Authorized industrial fuel system supplier
- ATEX compliant explosion-proof equipment
- Integration with fuel tanks and fuel systems
- Engineering & technical pump selection support
- Worldwide supply for fuel infrastructure projects
Pump Catalogue 2025
Full technical specifications, pump models and industrial transfer solutions
Request Product CatalogueRequest Technical Support or Quotation
Contact Neftgen for pump selection, datasheets and pricing:
Email: info@neftgen.com
Web: www.neftgen.com
WhatsApp: +90 533 655 22 51
Ex-Proof (Exproof) Diesel Pumps for Hazardous Areas
Neftgen ex-proof diesel pumps — also written “exproof” — are ATEX explosion-proof pumps built for Zone 1 and Zone 2 fuel handling. Every motor and electrical component is certified explosion-proof (Ex II 2G Ex IIB T4), so diesel, gasoline and fuel oil can be transferred safely in fuel depots, tank farms, mining sites and refuelling areas. Each ex-proof pump can be supplied loose or pre-installed on a Neftgen fuel transfer skid.
High-Flow ATEX Pumps — up to 2,300 L/min
For bulk fuel transfer and fast tanker unloading, Neftgen supplies high-flow ATEX diesel pumps delivering up to 2,300 l/min (138 m³/h), heads up to 76 m and motors from 0.25 to 30 kW. High-flow self-priming models hold prime on suction lifts up to the catalogue figure of 6 m and on intermittent duty — suitable for tank-to-tank transfer, road tanker unloading, mobile fuel stations and generator fuel supply systems. Send us your flow rate and head and we will select the right explosion-proof pump model for you.